Model |
PAR18-5 |
PAR36-3 |
Output
voltage |
Output voltage |
0 to 18V |
0 to 36V |
Setting resolution |
10mV |
Maximum output voltage |
18V |
36V |
Model |
PAR18-5 |
PAR36-3 |
Output
current |
Output current |
0 to 5A |
0 to 3A |
Setting resolution |
10mA |
Maximum output current |
5A |
3A |
Model |
PAR18-5 |
PAR36-3 |
Voltage regulation characteristics
(at times other than during voltage remote sensing
operation) |
Line regulation (with respect to ±10% variation in
AC) |
2mV |
Load regulation (with respect to change from 0 to
100%) |
5mV |
4mV |
Ripple/noise (10Hz to 1MHz) |
0.5mVrms |
Ripple peak (p-p) |
5.6mVp-p |
4.2mVp-p |
Transient response |
100µs Typ |
Temperature coefficient |
100ppm/°C Typ |
Model |
PAR18-5 |
PAR36-3 |
Current regulation characteristics
(at times other than during voltage remote sensing
operation) |
Line regulation (with respect to ±10% variation in
AC) |
4mA Typ |
3mA Typ |
Load regulation (with respect to change from 0 to
100%) |
20mA Typ |
15mA Typ |
Ripple/noise (10Hz to 1MHz) |
5mArms Typ |
4mArms Typ |
Ripple peak (p-p) |
10mAp-p Typ |
8mAp-p Typ |
Temperature coefficient |
200ppm/°C Typ |
Model |
PAR18-5 |
PAR36-3 |
Voltmeter |
Display (3-1/2 digits‚ LED) |
Maximum 19.99V display‚ fixed range‚ red LEDs |
Maximum 39.99V display‚ fixed range‚ red LEDs |
Accuracy (OUT ON) |
PAR18-5 :± (0.5%rdg 2digit) at 23°C±5°C 80%RH or
less PAR36-3 :± (0.5%rdg 4digit) at 23°C±5°C 80%RH or less |
Model |
PAR18-5 |
PAR36-3 |
Ammeter |
Display (3 digits‚ LED) |
Maximum 9.99A display‚ fixed range‚ red
LEDs |
Accuracy (OUT ON) |
± (1.0%rdg 2digit) at 23°C±5°C 80%RH or
less |
Model |
PAR18-5 |
PAR36-3 |
Functions |
OUTPUT ON/OFF |
Output on/off switch‚ but output cannot be switched
on when MEMORY is on (red LED lights when on) |
OUTPUT PROTECT ON/OFF |
Cut off the output if voltage or current setting
changed. (red LED lights when on) |
PRESET (1‚ 2‚ 3) |
3 sets of voltage and current values can be preset
(green LED lights when on). The setting contents of each preset can be
checked. |
MEMORY |
Presetting of voltage and current values is possible
(red LED lights when on). |
KEY LOCK |
All setting functions are fixed and all keys except
POWER are locked (red LED lights when on). |
EXT CONTROL ON/OFF |
On/off switch of EXT CONTROL terminal‚ current ;
100mA max applied voltage ; 60V max‚ open collector‚ active low (red LED
lights when on). |
V/A |
Voltage and current settings(green LED lights when
on) |
Model |
PAR18-5 |
PAR36-3 |
Output |
Polarity |
Positive or negative side groundable |
Terminal color |
‚ S (red)‚ -‚ -S (white)‚ and GND
(black) |
Groundable voltage limit |
±250V DC |
Voltage remote sensing |
Possible‚ within 1.0V from output
voltage |
Power consumption VA/W |
Approx. 264VA/213W |
Model |
PAR18-5 |
PAR36-3 |
|
Power requirement |
100V±10% AC‚ 50/60Hz‚ 120V/220V/240V±10% (MAX 250V
AC) internally switchable |
Case dimensions |
138(W)×147(H)×372(D)mm |
Maximum dimensions |
143(W)×167(H)×392(D)mm |
Weight |
Approx.8.0kg |
Accessories |
Instruction manual×1‚ Power cable×1‚ Modular cable |