¢Â Hioki 3290 Clamp-On AC/DC HiTester
  Á¦Á¶¿ø ¢º Hioki
  ¸ðµ¨¸í ¢º 3290
  ¿É ¼Ç ¢º
  ¿É ¼Ç ¢º
  ÆǸŰ¡°Ý ¢º 290,000¿ø
  Æ÷ÀÎÆ® ¢º 0¿ø
  ±¸ÀÔ¼ö·® ¢º °³
 
¢Ñ ±¸ÀÔ¹®ÀÇ : 02-2278-4054/01 ¶Ç´Â E-mail
 
   
  Á¦¸ñ ¾øÀ½

Hioki 3290
Clamp On AC/DC True RMS HiTester

All the Functions You Need for Measurement at DC or 1Hz and Up

  • Choice of three sensors (Example combinations)
    3290 + 9693: Measure up to 2000A
  • Choice of measurement methods
    DC (for battery measurement)
    AC+DC RMS (for full-/half-wave rectification measurement)
    AC RMS (for current distortion measurement)
    PEAK (for peak value measurement) of inrush current, etc.)
  • Choice of output (Simultaneous output)
    Effective value output, frequency output, waveform output
 
 
Note: Sensors are sold separately
Specifications
AC Current
ranges
3290 + 9693 : AC 200 to 2000A
AC+DC, AC RMS, AC MEAN
Other Current ranges 3290+9691 : DC 20 to 100A
3290+9692 : DC 20 to 200A
3290+9693 : DC 200 to 2000A
AC voltage ranges None
Other voltage ranges None
Other functions Frequency: 10 to1000 Hz
Analog output DC or AC Current : 2V/f.s.
Level output with REC mode
Waveform output with MON mode
Frequency : 1V/f.s.
Accuracy AC/DC/AC+DC Current :¡¾ 1.3 % rdg. ¡¾ 3 dgt. (Typical)
Frequency
(at50 or 60Hz)
¡¾ 0.3 % rdg. ¡¾ 1 dgt. (Typical)
Frequency characteristics DC to 1kHz ¡¾ 2.3 % rdg. ¡¾ 8 dgt.
Display Digital / LCD maximum 2000 dgt. Bar graph / 20 seg.
Sampling rate Fast : 4 times / sec
Normal : 2 times / sec
Slow : 1 time / 3sec
Crest factor 2.5 or less
Effect of external
magnetic fields
9693 : 2.0 A equivalent max. at 400 A/m
Max. circuit voltage 600 V AC rms. (insulated wire)
Core jaw diameter 9691: 35 mm; 9692: 33 mm; 9693: 55 mm
Power supply Type 3 alkaline dry cell (LR6) ¡¿ 4, or AC adapter
Dimensions (WxHxD), Mass 9693: 62 mm (2.44") x 196 mm(7.72") x 35 mm(1.38"), 500 g (17.6 oz)

º»Ã¼(3290)+AC/DC_Clamp2000A(9693)+Ä«¹Ù+ÀϺ»¾î¸Þ´º¾ó+Àü¿ø¾Æ´äŸ+Ãâ·ÂÄÉÀ̺í+º¯È¯¾Æ´äŸ

Ä«´Ù·Î±×º¸±â

   
 
 
 
HOME | ȸ»ç¼Ò°³ | °³Àκ¸È£Á¤Ã¥ | Contact US | ÀÌ¿ë¾à°ü | ÀÌ¿ë¾È³»
  »ç¾÷ÀÚµî·Ï¹øÈ£ : 101-34-95557 | Åë½ÅÆǸž÷½Å°í : Á¦01-4938È£
°³ÀÎÁ¤º¸ º¸È£´ã´çÀÚ : ¹Úº´°Ç | ¹®ÀÇÀüÈ­ : 02-2278-4054/01
ÁÖ¼Ò : ¼­¿ïƯº°½Ã ±¸·Î±¸ °æÀηΠ53±æ 15 ¶óµ¿ 2718È£ (±¸·Îµ¿,Áß¾ÓÀ¯Åë´ÜÁö)

Copyright ¨Ï ¼¼·Ð°èÀü All rights reserved. Anyquestions to seroni@naver.com