Advantest R12702A Resistivity Chamber
  제조원 Advantest
  모델명 R12702A
  소비자가 450,000원
  판매가격 280,000원
  포인트 0원
  구입수량
 
☞ 구입문의 : 02-2278-4054/01 또는 E-mail
 
   
  제목 없음

Overview

The 12702A/B resistivity chamber is a shield box containing electrodes. Together with an electrometer, it is used to measure the volume resistivity and surface resistivity of sheet, filmy and platy samples. The pressure of the electrodes can be varied according to the sample used, allowing the sample to be fixed firmly regardless of its hardness. The chamber has a capability to measure the sample thickness necessary to calculate the volume resistivity by using a micrometer. In addition, it is provided with a volume/surface resistivity measurement switch and an applied voltage ON/OFF switch which turns on and off according to opening and closing of the cover

12702A 저항률 챔버는 전극을 포함하는 차폐 박스이다.전위계 함께, 그것은 시트, 필름 상 판상 샘플의 체적 저항율 및 표면 저항률 측정하기 위해 사용된다.전극 압력은 시료가 완전히 관계없이 경도가 고정 될 수 있도록 사용되는 샘플에 따라 변할 수있다.챔버는 마이크로 미터를 사용하여 체적 저항률을 계산하는데 필요한 샘플 두께를 측정하는 능력을 갖는다. 또한, 볼륨 / 표면 저항 측정 스위치를 구비하고,인가 전압 ON / OFF 스위치 커버의 개폐에 따라 오프되는 스위치를 구비하고 있습니다

 .

Specifications

Operating environment Temperature: -20°C to +80°C
Relative humidity: 80% or less, No condensation
Storage environment Temperature: -25°C to +80°C
Relative humidity: 80% or less, No condensation
Electrode size
  12702A 12702B
Main electrode 50mm dia. 70mm dia.
Guard electrode (outer)
Guard electrode (inner)
80mm dia.
70mm dia.
100mm dia.
90mm dia.
Opposed electrode 103mm dia.
Insulation resistance 
(0 to 40°C, 70%RH or less,1000VDC)
Main electrode-guard electrode: 
1 × 1015Ω or more
Main electrode-opposed electrode: 
1 × 1015Ω or more
Guard electrode - opposed electrode: 
1 × 109Ω or more
Dielectric strength Opposed electrode - ground: 1.5 kV (1 minute)
Guard electrode - ground: 1.5 kV (1 minute)
Maximum sample size 130 (W) × 10 (H) × 130 (D) mm
Minimum sample size 85mm /105mm dia. or more
Connector INPUT A triaxial connector
INPUT B M-type connector
V SOURCE binding post
Pressure range of electrode 2 kg to 5 kg
Sample thickness measurement range 0 to 10mm (1/100mm resolution)
Dimensions Approx. 167 (W) × 186 (H) × 207 (D) mm
Mass 2.6 kg or less

 

   
 
 
 