¢Ñ ÇöÀçÀ§Ä¡ : HOME ¡· °íÀå/¼ö¸®ºÎǰ ¡·Áß°í°èÃø±â ǰÀý¸ñ·Ï ¡·Tektronix[75]
¢Â Tektronix Voltage Isolation Systems
  Á¦Á¶¿ø ¢º Tektronix
  ¸ðµ¨¸í ¢º A6909
  ¿É ¼Ç ¢º Àü¿ë Probe*2°³ Æ÷ÇÔ
  ¼ÒºñÀÚ°¡ ¢º 0¿ø
  ÆÇ¸Å°¡°Ý ¢º 0¿ø
  Æ÷ÀÎÆ® ¢º 0¿ø
  ±¸ÀÔ¼ö·® ¢º »óǰÀ» °ð ÁغñÇϵµ·Ï ÇϰڽÀ´Ï´Ù.
 
¢Ñ ±¸ÀÔ¹®ÀÇ : 02-2278-4054/01 ¶Ç´Â E-mail
 
   
  Á¦¸ñ ¾øÀ½

Voltage Isolation Systems

A6906

Features

A6906
  • For Floating Signals to ¡¾850 V
  • 60 MHz
  • Monolithic
  • 2 Channels
  • CMRR: 60dB @ 1 MHz
  • GPIB
  • Push-button Self-calibration of Offset and Gain
  • Each Channel Can Be Individually Set for Coupling and Attenuation

Applications

  • Motor Drives
  • Power Supplies
  • Electronic Ballast
  • UPS Systems
  • Switch Mode Control
  • Power Semiconductors

A6907 Voltage Isolators

The A6906 monolithic voltage isolators are essential tools for power conversion design. Accurate floating measurements are required to design and verify high-performance switch mode circuits. The A6906 offers safety, performance, multiple isolated channels (A6906-tow), direct connection to the measurement instrument and simplified controls in a single box. The A6906 offers high performance and safety for the lowest cost per channel.

The A6906 isolator features a bandwidth of 60 MHz, slew rate of 20,000 V/µs and CMRR of 60 dB (1,000:1) at 1 MHz and GPIB control in a package the size of a Tektronix TDS Oscilloscope. The ¡¾850 V probes plug directly into the isolator and are specifically designed for safe connection to floating circuits and enhanced CMRR

Characteristics

Electrical

Attenuation Settings - 2,000X to 1X (100 mV/div to 200 V/div with oscilloscope set to 100 mV/div) in 1-2-5 steps.

Full Range Measurements - ¡¾2 mV to ¡¾850 V.

Frequency Response Bandwidth - 60 MHz (-3 dB).

Transient Response - Rise Time: <7.0 ns 100 mV/div and 200 mV/div. <5.8 ns 500 mV/div to 200 V/div.

Maximum Working Voltage - 600 VRMS, 850 V (DC + peak AC).

Input Impedance - Resistance: 10 megaohm. Capacitance: 4.5 pF, ¡¾0.5 pF.

Output Impedance - 50 Ohm.

Output Drive - ¡¾500 mV into 50 Ohm load.

Maximum Common to Ground Slew Rate - 20,000 V/µs.

Offset Accuracy - ¡¾20 mV.

Delay - Approximately 30 ns with 1.5 m probe cable.

Safety - UL1244, EN61010-1.

CMRR

60 Hz >105 dB (100 mV/div),
>100 dB (1 V/div)
1 MHz >60 dB (100 mV/div),
>45 dB (1 V/div)
10 MHz >50 dB (100 mV/div),
>40 dB (1 V/div)

Power Requirements

Line Voltage Ranges - 90-250 V AC.

Line Frequency Range - 47-66 Hz.

 

   
 
 
 