¢Â Fluke Documenting Process Calibrator
  Á¦Á¶¿ø ¢º Fluke
  ¸ðµ¨¸í ¢º 702
  ¿É ¼Ç ¢º º»Ã¼, ȣȯ¾Æ´äŸ(ÃæÀü¼¼Æ®Á¦¿Ü)
  ¼ÒºñÀÚ°¡ ¢º 0¿ø
  ÆǸŰ¡°Ý ¢º 0¿ø
  Æ÷ÀÎÆ® ¢º 0¿ø
  ±¸ÀÔ¼ö·® ¢º »óÇ°À» °ð ÁغñÇϵµ·Ï ÇÏ°Ú½À´Ï´Ù.
 
¢Ñ ±¸ÀÔ¹®ÀÇ : 02-2278-4054/01 ¶Ç´Â E-mail
 
   
  Á¦¸ñ ¾øÀ½

Documenting Process Calibrator

The Fluke 702 Process Calibrator is an easy-to-use field calibrators designed specifically for use on control instrumentation in process plants. Rugged packaging allows the calibrator to perform dependably despite rough handling and hostile plant environments, while automatic documentation capabilities save time and ensure accurate results. Because the 702 is a multipurpose tool, you can use them for troubleshooting and maintenance as well as calibration.

 

Fluke 702 Features:

  • Calibrate temperature, pressure, voltage, current, resistance, and frequency
  • Simultaneously measure and source
  • Automatically capture calibration results
  • Document procedures and results to meet ISO 9000, EPA, FDA, OSHA and other requirements
  • Measure/simulate eleven types of thermocouples and eight RTDs
  • Store up to 8,000 readings in data logging mode
  • PC interface
  • Weight: 3 lb 1 oz
  • Internal Battery Pack: NiCd, 7.2V, 1700 mAh
  • Battery Life: Typically over eight hours

Fluke 702 Specifications:

Measure Range (full scale) 110.000 mVdc - 300.00Vdc; Vac, 20 Hz to 5 kHz; 30.00 mA dc - 110.00 mA dc; 11.000¥Ø - 11.000 k¥Ø; 1.00 Hz to 50.00 kHz
Source Range (full scale) 110.000 mV; 1.10000V; 11.00000V; Source 22.000 mA; Simulate 22.000 mA; 11.000¥Ø - 11.000 k¥Ø; 2.00 Hz to 50 kHz
Temperature, RTDs
and Thermocouples
10¥Ø Cu(427); 100¥Ø Pt(3916); 100¥Ø Pt(3926); 100¥Ø (385); 200¥Ø Pt(385); 500¥Ø Pt(385); 1000¥Ø Pt(385); 120¥Ø Ni(672); E, N, J, L, K, T, U, B, R, S, C
Data Log measure V, mA, ohms, frequency, temperature, pressure 1 to 60 readings/min, 8000 readings max
Ramp source V, mA, ohms, frequency, temperature 4 steps/sec
Loop Power selectable, 24V or 28V; 22 mA max

PDFÆÄÀϺ¸±â

   
 
 
 
HOME | ȸ»ç¼Ò°³ | °³Àκ¸È£Á¤Ã¥ | Contact US | ÀÌ¿ë¾à°ü | ÀÌ¿ë¾È³»
  »ç¾÷ÀÚµî·Ï¹øÈ£ : 101-34-95557 | Åë½ÅÆǸž÷½Å°í : Á¦01-4938È£
°³ÀÎÁ¤º¸ º¸È£´ã´çÀÚ : ¹Úº´°Ç | ¹®ÀÇÀüÈ­ : 02-2278-4054/01
ÁÖ¼Ò : ¼­¿ïƯº°½Ã ±¸·Î±¸ °æÀηΠ53±æ 15 ¶óµ¿ 2718È£ (±¸·Îµ¿,Áß¾ÓÀ¯Åë´ÜÁö)

Copyright ¨Ï ¼¼·Ð°èÀü All rights reserved. Anyquestions to seroni@naver.com