¢Ñ ÇöÀçÀ§Ä¡ : HOME ¡· °íÀå/¼ö¸®ºÎÇ° ¡·Áß°í°èÃø±â Ç°Àý¸ñ·Ï ¡·±âŸ ¸ÞÀÌÄ¿[114]
¢Â DC Power Supply
  Á¦Á¶¿ø ¢º KENWOOD
  ¸ðµ¨¸í ¢º PS6-120
  ¼ÒºñÀÚ°¡ ¢º 0¿ø
  ÆǸŰ¡°Ý ¢º 0¿ø
  Æ÷ÀÎÆ® ¢º 0¿ø
  ±¸ÀÔ¼ö·® ¢º »óÇ°À» °ð ÁغñÇϵµ·Ï ÇÏ°Ú½À´Ï´Ù.
 
¢Ñ ±¸ÀÔ¹®ÀÇ : 02-2278-4054/01 ¶Ç´Â E-mail
 
   
  Á¦¸ñ ¾øÀ½
¡Ü Ư¡
  • ¼ÒÇü °æ·®ÀÇ °í¼º´É : Å©°í ¹«°Å¿î ÀϹÝÀûÀÎ Àü¿ø °ø±Þ±âÀÇ Àý¹Ý Á¤µµÀÇ Å©±â·Î °¡º­¿ì¸ç °í¼º´ÉÀ» ¹ßÈÖ
  • Àü¾Ð,Àü·ù µðÁöÅРǥ½Ã : Àü¾Ð°ú Àü·ù Ãâ·Â ·¹º§À» 7 ¼¼±×¸ÕÆ® LED·Î µ¿½Ã¿¡ Ç¥½Ã
  • GP-IB ½Ã½ºÅÛ °â¿ë¼º : Ãâ·Â Àü¾Ð°ú Àü·ù, ´Ù¾çÇÑ ½ÅÈ£ Ãâ·Â,Ãâ·Â°ú Àü¿ø On/Off ½ºÀ§Ä¡¿Í ¿ø°Ý/·ÎÄà ºÐ¸®±â¸¦ Á¶ÀýÇÒ ¼ö ÀÖ´Â Á¦¾î±â¸¦ °®Ãß°í ÀÖÀ¸¸ç GP-IB Á¦¾î ½Ã½ºÅÛÀ¸·Îµµ Á¶Á¤°¡´É(¼±Åûç¾ç GP-600)
  • Æø ³ÐÀº ÀÀ¿ë : Ãâ·Â Àü¾Ð°ú Àü·ù´Â ¿ÜºÎ Àü¾Ð Á¦¾î¿Í ¿ÜºÎ ÀúÇ× Á¦¾î¸¦ Æ÷ÇÔÇÏ¿© ´Ù¾çÇÑ ¹æ¹ýÀ¸·Î Á¶Á¤ °¡´É
  • ³·Àº ³ëÀÌÁî : ³Ã°¢ ÆÒÀÇ ¸ðÅÍ´Â ¿Âµµ ¼¾¼­¿¡ ¿¬°áµÇ¾î ÀÖ¾î ºÎÇÏ ¶Ç´Â ¿Âµµ°¡ ³·À» ¶§ ÀÚµ¿À¸·Î ÆÒ ¼Óµµ¸¦ ³·Ãß¾î °úµµ ³ëÀÌÁ ¹æÁöÇϴµ¥ µµ¿òÀÌ µÊ
  • Àü¸é °ø±â ÈíÀÔ±¸ : °í¹Ðµµ ·¢¿¡ Àß ÀåÂøµÉ ¼ö ÀÖµµ·Ï Á¦À۵ǾúÀ¸¸ç, Àü¸é ÆdzÚÀÇ ±×¸±À» ÅëÇØ °ø±â°¡ ÈíÀÔÇÏ´Â ¹æ½ÄÀ» »ç¿ëÇÏ¿© °­·ÂÇÏ°Ô ³Ã°¢ ÇÒ ¼ö ÀÖÀ½.
    Àü¸é ±×¸±¿¡´Â Á¦Ç° ³»ºÎ·Î µé¾î¿À´Â ¸ÕÁö¸¦ ¸·±â À§ÇÑ °ø±â ÇÊ´õ°¡ ³»Àå
  • µðÁöÅÐ µð½ºÇ÷¹ÀÌ : Àб⠽¬¿î 7 »¡°£ ¼¼±×¸ÕÆ® Ç¥½Ã±â´Â Àü¾Ð°ú Àü·ù ·¹º§À» µ¿½Ã¿¡ Ç¥½ÃµÇ¸ç Àü¾Ð°ú Àü·ùÀÇ 3-1/2 ÀÚµ¿ ¹üÀ§ Ư¡Àº °¢°¢ ÃÖ´ë 10mV¿Í 10mAÀÇ ºÐÇØ´ÉÀ¸·Î Ç¥½ÃµÊ
  • ¡Ü SPECIFICATIONS

    Model Output CV (constant-voltage) characteristic CC (constant-current) characteristic Others
    CV CC Ripp1 Line
    regul.
    Load
    regul.
    Trans.
     resp.
    2
    Rise/Fall time Ripple3 Line
    regul.
    Load
    regul.
    Input
    Current
    Case
    dim.
    ¹«°Ô
    V A mV
    rms
    0.05%
    + mV
    0.1%
    + mV
    m sec m sec
    (F.L)
    mA
     rms
    0.2%
    + mA
    0.2%
    + mA
    AC
     (100/
    200V)A
    Type kg
    (appr.)
    PS
    6-60
    0 to 6 0 to 60 10 5 5 1 80/150 120 5 5 8/5 I 3.0
    PS
    6-120
    0 to 120 2 260 10 10 16/10 II 5.5
    PS
    10-35
    0 to 10 0 to 35 10 5 5 1 80/150 70 5 5 8/5 I 3.0
    PS
    10-70
    0 to 70 2 160 10 10 15/9 II 5.5
    PS
    20-18
    0 to 20 0 to 18 10 5 5 1 80/150 40 5 5 8/5 I 3.0
    PS
    20-36
    0 to 36 2 92 10 10 15/9 II 5.5
    PS
    20-54
    0 to 54 15 120 15 15 22/13 III 7.0
    PS
    36-10
    0 to 36 0 to 10 10 5 5 1 80/150 20 5 5 8/5 I 3.0
    PS
    36-20
    0 to 20 2 60 10 10 15/9 II 5.5
    PS
    36-30
    0 to 30 15 80 15 15 22/13 III 7.0
    PS
    60-6
    0 to 60 0 to 6 10 5 5 1 80/150 12 5 5 8/5 I 3.0
    PS
    60-12
    0 to 12 15 2 44 10 10 15/9 II 5.5
    PS
    60-18
    0 to 18 20 55 15 15 22/13 III 7.0

    *1: Between 20 Hz and 1 MHz.
    *2: The time taken by the output voltage to return to within 0.1%+10 mV of the set value when the output current is varied from 20% to 100% at 50% to 100% of the rated output voltage.
    *3: Measured when the output voltage is between 1% and 100% of the rated voltage.

    Common Specifications
    Power source 85 to 132V /170 to 250V, AC 50 to 60Hz
    Display instruments ¡¡
    Voltmeter Display 3-1/2 digits red LED
    Accuracy 0.1%rdg¡¾2digits (23¡¾5¡ÆC)
    Temperature coefficient ¡¾100ppm/¡ÆC (0 to 50¡ÆC)
    Ammeter Display 3-1/2 digits red LED
    Accuracy 0.5%rdg¡¾3digits (23¡¾5¡ÆC)
    Temperature coefficient ¡¾200ppm/¡ÆC (0 to 50¡ÆC)
    Protection ¡¡
    Over voltage protection The power relay is tripped when the output voltage is exceeded by approx. 110%. of the rated voltage.
    Over current protection The power relay is tripped when the output current is approx. 110% to 130% of the rated current.
    Overheating Protection The power relay is tripped when the temperature of the heat sink is approx. 100¡¾5¢®ëC or more.
    Thermal fuse Built-in thermal fuse
    Input fuse Cut off the power relay
    Environmental condition ¡¡
    Temperature/humidity for operation 0 to 50¡ÆC/30 to 80%RH
    Temperature/humidity for storage -20 to 70¡ÆC/20 to 80%RH
    Cooling system Forced air (fan), front air intake type.
    Functions Automatic output switch resetting, voltage/current limit switch, preset OVP
    Case dimensions ¡¡
    Type I 70 (W) ¡¿ 124 (H) ¡¿ 350.5 (D) mm
    Type II 140 (W) ¡¿ 124 (H) ¡¿ 350.5 (D) mm
    Type III 210 (W) ¡¿ 124 (H) ¡¿ 350.5 (D) mm
    Accessories 2.5m AC cable ¡¿ 1

     

       
     
     
     