P6417 |
P6418 |
P6419 |
P6434 |
Probe Type |
Single-ended Data
Single-ended Clock
(General Purpose) |
Single-ended Data
Single-ended Clock
(General Purpose) |
Single-ended Data
Single-ended Clock
(Compression 17-channel) |
Single-ended Data
Single-ended Clock
(Mictor 34-channel) |
Number of Channels |
17 |
17 |
17 |
34 |
Recommended Use |
For most general-purpose applications that require more flexible signal
attach. |
For most general-purpose applications. |
For Applications requiring good signal density and quick reliable
attachment. |
Recommended for applications requiring many channels to be quickly connected
in a small footprint |
Attachment to Target System |
Fits both 0.100 in and 2 mm square pin configurations. |
Compression Elastomer |
Amp Mictor 34 Channel Connector |
Probe Loading AC/DC |
2 pF/20 k¥Ø to 0 V (TLA5000) |
1.4 pF/20 k¥Ø to 0 V (Data) (TLA5000) |
< 0.7 pF/20 k¥Ø to 0 V (TLA5000) |
2 pF/20 k§Ù to 0 V (TLA5000) |
2 pF/20 k¥Ø to 2.2 V (TLA600, TLA7N/P/Qx) |
2 pF/20 k§Ù to 0V (Clock) (TLA5000) |
< 0.7 pF/20 k¥Ø to 2.2 V (TLA600, TLA7N/P/Qx) |
2 pF/20 k¥Ø to 2.2 V (TLA600, TLA7N/P/Qx) |
|
1.4 pF/20 k¥Ø to 2.2 V (TLA600, TLA7N/P/Qx) |
|
|
|
2 pF/20 k¥Ø to 2.2 V (TLA600, TLA7N/P/Qx) |
|
|
Input Range |
-5 V to 8 V |
Max Voltage (non-destruct) |
¡¾15 V |
Cable Length |
1.8 m (6 ft.) |